YX65-330 Aluminum Magnesium Manganese Plate
Standard accessories and tools for aluminum magnesium manganese alloy roof systems 1.3.1 Fixed bracket The height of the fixed bracket can be selected according to the structural requirements, commonly used ones are: 81 mm, 106 mm, 116 mm, 156 mm, and there is a 6mm thick insulation pad under the bracket. The width of standard bearings is 58 millimeters, and the width of double width bearings is 116 millimeters. 1.3.2 Accessories 1) Gable joint accessories 2) Gutter and eaves joint accessories Eave gutter and eaves accessories 1.3.3 Tools 1) Electric edge locking machine is used to lock the rib of the plate and firmly connect the plate to the fixed seat 2) Manual edge locking machine: Before using the electric edge locking machine, use the manual edge locking machine to lock the end of the board tightly, so that the electric edge locking machine can be in place 1.4 Functional Guarantee of Al Mg Mn Alloy Roof System 1.4.1 Sound absorption and insulation 1) Sound absorption The system uses sound-absorbing materials to adjust the sound field distribution to eliminate echoes. Solution: Roof floor perforation+laying sound-absorbing materials (non-woven sound-absorbing cloth, glass fiber cotton) 2) Sound insulation Used to isolate outdoor noise sources. Solution: Choose the appropriate roof structure and material quality (doubling the quality and improving sound insulation by 6dB); The roof adopts a double-layer or multi-layer air sandwich structure to minimize the rigid connection between the two layers (i.e. sound bridge) and avoid reducing additional sound insulation. 1.4.2 Insulation It is required to control the internal surface temperature of the enclosure structure to not be lower than the indoor temperature, ensuring that the surface does not condense. 1) The reason for condensation Because the surface temperature of the object is lower than the temperature. In steel structures, metal cladding is connected to purlins through fasteners. If special treatment is not carried out, condensation will occur in the parts connected by these metals. When there is an inner liner, due to the cold bridge effect, the temperature of the liner decreases, making it difficult for water vapor to pass through the liner, resulting in obvious water droplets on the liner. 2) Condensation hazards If the insulation performance of the insulation cotton is changed, water vapor may cause dripping and rusting of the veneer; The contact between water vapor and steel components may cause rust and shorten the service life of the roof. 3) Anti condensation design Setting up steam insulation layer: It should be set on the side where water vapor flows in, so the heating room should be set inside the insulation layer, and the cold storage building should be set outside the insulation layer. The material selection for polypropylene ribbed veneer is ideal, while aluminum foil veneer is prone to rusting in the presence of water vapor and should be avoided. Setting up ventilation layers or exhaust channels: If there is an outer insulation layer between the ventilation layers and the roof panel, steam infiltration can take away indoor airflow and continuously exchange with outdoor air, acting as a drying insulation layer.
|