YX130-300-600 Color Steel Roof Panel

  • DETAILS

1. Roof ridge

The peak at the ridge is too high to ensure the waterproofing of the roof cover plate; Vertical overlap without mortar or silicone, forming gaps and causing water leakage; The longitudinal overlap of the roof cover plate is connected with rivets, which break due to insufficient thermal expansion and contraction strength, causing water leakage; Not laying a plug between the roof cover plate and the roof panel, or causing the plug to fall off due to irregular placement, resulting in water leakage.

2. Lighting board position

The peaks on both sides of the daylighting panel are higher than the roof panel. After installation, the airtight seal causes a pressure difference between the inside and outside of the daylighting panel, and capillary water enters the roof through the gaps on both sides of the daylighting panel. The longitudinal overlap length of the daylighting board is insufficient, resulting in mortar aging and loss of adhesion. Longitudinal mortar detachment. The daylighting board is rigidly overlapped with the color steel plate, and the gap in the middle is not sealed. To prevent water leakage from roof lighting panels, attention should be paid to the following aspects: waterproof screws should be installed on the upper part of the wave peak; The edge sealing plate at the daylighting board should be firmly sealed with the daylighting board, and the mortar on both longitudinal sides should be widened and laid on the upper part of the wave peak to prevent capillary water from infiltrating.

3. The eaves are the main source of water leakage

No foam plug is installed on the outer roof plate, and the outer roof floor is not moved down; The length of the outer wall of the wall is not sufficient, and the eaves area is not waterproof.

4. Trench section

There are gaps in the welded joints of the inner groove, forming water seepage; The diameter design of the ditch and rainwater pipe is too small, which does not match the slope length of the factory building; There is no headboard at the end of the drainage ditch; The length of the roof outer panel extending into the gutter is not enough, and water will flow back into the factory building.

5. Location of roof gas tower

Foam plugs shall not be placed on the ground and roof of buildings, and glue or silica gel shall not be laid on one side of the ground. The outdoor roof is not connected to the building, and the open part of the empty tower structure has not been treated for water leakage.

6. Top plate opening position

The opening is not waterproof according to the design node, and the steel plug is not laid with waterproof mortar or silicone; The reserved area around the opening is small, and rainwater flow is not smooth, making it easy to accumulate water; The edges around the opening are not waterproof; There is no added structure around the opening, forming low concave water; There is a phenomenon of water blockage during waterproofing construction, resulting in accumulated water.


1689300500768569.jpeg