Textile Factory Buildings

  • DETAILS

1. The characteristics of light steel structures in textile industry factories are generally divided into ordinary steel structures and light steel structures, with no clear boundary between them. The calculation rules are the same. The so-called light steel structure is generally a type of structure with small structural loads, small structural components, and thin component walls. Generally speaking, portal steel frames, roof trusses, and spatial trusses are the main load-bearing structures. Due to the small load acting on light steel structures, the internal forces generated by structural effects are generally small, which makes the strength of the structure often not a problem. Due to the small cross-section of the components, the inertia distance of the cross-section is small, and the stiffness of the structure is also reduced. The overall and local stability of the structure has become a major concern in design. This is the characteristic of light steel structures. To understand this characteristic, corresponding measures can be taken, such as increasing support and support to meet the requirements of component slenderness ratio, adding reinforcement bars to meet the local stability of the component, etc.

2. The structure of a portal frame lighthouse generally consists of a main frame and a supporting system. The supporting structure includes: 1) wall frame; 2) Purlins; The support system includes: 1) vertical support between rigid frame columns; 2) Horizontal support between rigid frame beams; 3) Rigid pull rods and pull rods; Corner braces, etc.


1715072593607469.jpeg

       

3. Purlin design

1. Purlin function: to bear roof loads and transfer them to the rigid frame. Purlins are also connected to various rigid frames through bolts, forming a spatial structure with the rigid frames and wall frame beams. 2. Purlin form: solid net purlin, open net purlin, grid purlin. 3. Determination of section height: The section height h of solid web purlins is generally 1/35 to 1/50 of the span; The height h of the truss purlin section is generally 1/12 to 1/20.4 of the curvature. Stage determination: Part of the race B of the solid web purlin is selected based on the steel specifications, and part of the height h. The total width B of the space truss's upper chord purlin is 1/1.5~1/2 of the total section height with load. 1) The roof material with static load weight supports and weighs the purlin structure. 2) The value of the irregular steel plate with live load on the bare roof surface (0.50 kn/m2.6) is calculated and arranged according to the horizontal projection area. The connection and structure of the truss purlin (arrangement and laying of purlins on the rigid frame) should be located at the node of the top chord of the truss to avoid bending moment at the top chord of the truss. When using internal drainage channels, the edges of the purlins should be closed. The edge of the purlin should be as close as possible to the ditch. 2) For channel steel and Z-shaped purlins, the end of the upper flange (or rotation) should face the ridge to reduce torsion caused by eccentricity of the roof load. 3) The top chord of the truss purlin should be perpendicular to the top chord of the roof truss, and the web and bottom chord should be perpendicular to the ground.

4) Ridge purlin scheme: Generally, a double purlin scheme is adopted, and the ridge purlin can be made of channel steel, angle steel, or round steel. The connection between the purlins and the roof should be reliable to ensure that the roof can prevent lateral instability and torsion of the purlins, which is particularly important for solid web purlins that have not been checked for overall stability. The connection between purlins and profiled steel sheet roofs should use self tapping screws with rubber washers. The connection between the end of the purlin and the rigid frame should be able to prevent torsion of the cross-section at the end of the purlin, thereby improving its overall stability. 1) Angle steel purlin brackets can be installed at the connection between solid web purlins and rigid frames to prevent torsion deformation and overturning of the purlins at the support points. There shall be no less than 2 connecting bolts between the end of the purlin and the purlin support, and they shall be set along the height direction of the purlin. 2) The truss purlins are generally directly connected to the top chord of the truss using bolts. The setting of purlin support and pillar 1 support: The setting of purlin support is mainly related to the lateral stiffness of the purlin. For light H-steel and space truss purlins with high lateral stiffness, support is generally not required. For solid web and face truss purlins with poor lateral stiffness, in order to reduce lateral deformation and torsion of the purlins during installation and use, and ensure their overall stability, it is generally necessary to set supports between the purlins as lateral support points.

When the purlin is less than or equal to 4 meters, the need for support can be determined according to the calculation requirements; When the roof slope is greater than 1/10 and the span of the purlins is greater than 4. support should be set in the middle of the span of the purlins; When the span is greater than 6 m, bracing or bracing shall be set at the third point of purlin span, and slant support and bracing shall be set at cornice. The diameter of the support rod is 8-12mm, selected based on the load and the distance between the purlins. 2) Purlin side bending and purlin side bending are the two main forces acting on purlins. The slenderness ratio of the pillar is required to be less than or equal to 220. and steel pipes, square steel pipes, or angle steels can be used. There is currently another method of setting up supports inside steel pipes, which has a simple structure. At the same time, set slant support. The connection between diagonal braces and purlin web plates should generally be bent, and the length of the straight section should not be too large to avoid local bending after being subjected to force. The distance between the bending point and the web should be 10-15mm. If conditions permit, diagonal straps can be connected by diagonal plates or angle steels instead of bending connections.


1715072574355710.jpeg

       

4. Determine roof support and column support

1) The main function of supports is to ensure that the structural system becomes a spatial system with sufficient spatial stiffness.

2) The support is mainly subjected to wind load, seismic action, and temperature action.

3) When calculating the internal forces of supports, it is generally assumed that the nodes are hinged and the influence of eccentricity is ignored. In addition, the general support is considered as a tie rod, so it is generally suitable for bi-directional arrangement. 1. The force on the top plate support is relatively small, and the support section can be selected according to the allowable slenderness ratio. Cross diagonal rods and flexible thin rods can be designed according to the pulling angle, and a single angle steel can be used; Non intersecting diagonal rods, chord rods, vertical rods, and rigid tie rods can be designed with compression angles, and double angle steel can be used to form sections or cross-sections. When the span of the roof truss is large, the building height is high, and the basic wind pressure is also high, the section of the components should be determined based on the internal forces calculated by the truss system. When calculating the internal forces of supporting components, it can be assumed that the compressed components in the cross diagonal components lose power under horizontal loads, and the force is only applied by the tension rod. For the factory building, the inter column support is divided into upper support and lower support. When calculating the upper support, in order to avoid significant temperature stress caused by excessive stiffness of the support, the support web is calculated according to flexible tensioning. The lower support of the cross shaped system is usually round steel for small cranes, and angle steel or channel steel for large cranes. Cross diagonal rods are usually designed based on tie rods, but in order to improve the longitudinal stiffness of the factory building, when the crane is large, it should be designed based on tie rods.

5. The functions and settings of angle braces

The function of corner braces is to prevent instability of the lower flange of the beam and the inner flange of the column. In design calculations, reducing the out of plane calculation length of beams and columns is detrimental to the spacing between side supports. The reason for setting angle braces is the variation of force on the inclined beam of the rigid frame. Under the combined use of dead and live loads, the stress of a beam is generally compressive at the upper flange and tensioned at the lower flange. Therefore, the effective connection between the purlins and the steel beam provides reliable support for the stability of the upper flange. Therefore, in general, the out of plane calculated length of a beam is twice the spacing between purlins. It can ensure the stability of the upper flange. However, when wind suction loads are applied, the lower wing edge is compressed and the upper wing edge is pulled out, so there is no reliable out of plane support for the stability of the lower wing edge. Therefore, angle braces are added to the lower flange of the beam to provide support for the lower flange of the steel beam. One end of the diagonal brace is connected to the lower flange of the beam, and the other end is connected to the purlin.

The application of angle support is detailed in the "Specification for Portal Frames". Research on failure and collapse has shown that portal frames are composed of flange buckling compression in many cases, and the intersection of inclined beams and columns under compressive stress is an important component of the structure. This regulation stipulates that "angle braces shall be installed near the green connection point between the rigid frame beam and the column inner wing at the eaves position, at the purlins and wall beams" to ensure the stability of the site. In addition, it is stipulated to set up angle braces with a spacing not exceeding 16 (235/F3), which corresponds to 1/2 times the width of the compressed flange. This regulation is easy to implement and also facilitates construction quality inspection. If the flange ring is narrow, the spacing between the angle braces should be reduced. It is specifically stipulated in the regulations that when there is no angular support at the lower flange of the inclined beam, reliable measures such as setting rigid support or expanding the section should be taken to ensure the stability of the rigid frame. This ensures the safety of the structure. As for the angle brackets of the columns, they should be set according to the specific situation. When the height of the column is large, it is necessary to check the plane stability according to the cross-section. A corner brace is usually not enough, and in this case, several corner braces should be set up.


1715072555950027.jpeg